There is a gas turbine just come from general overhaul, RH ~ 0 hour.
Its power turbine exhibit high vibration at 1xRPM, and phase can not differentiate between unbalance or misalignment. Axial vibration relatively small.
Alignment recheck, field balancing, and rotate coupling hub had been done to solve the problem, but not solved the problem. NGP was still 94%-95%, with PT Vibration 0.4 ips pk.
Another clue was get. The vibration increase after after engine had run for some time, e.q: 2-4 hours. So it is suspected related to thermal growth problem, so: alignment. After check alignment target specification there was misunderstanding between field maintenance people, they used old standard before the centrifugal booster compressor restaged. So after the alignment redone with new alignment specification target, the PT Vibration run low, NGP can be increased.
But, unfortunately, at NGP 99%, T5 topping appeared. PCD at TCP was about 118 psig, PCD at dial gage at panel was about 123 psig. Inlet air filter dp was 2.0" WC. T5 compensator had been reset to match engine specs T5 Base, IGV angle was 4 degrees. Bleed valve gave no sign of leak.
So we planned to cek PCD gage, inlet air filter dp gage, swap T5 tehrmocouple, and check bleed valve, and wonder that why IGV set was so small (range = 3 deg - 9 deg) that can caused low inlet air flow.
After PCD gage checked, it is confirmed that gage of TCP is correct, actual. Low PCD is confirmed.
And next day it's found that inlet air dp actual pressure is 4.8" WC. So, we suspected that dirty/semi blocked inlet air filter was caused of T5 topping problem. But, unfortunately after all inlet air filter had been changed, the T5 problem still the same, even with inlet air new filter and inlet air dp low.
Then we tried to adjust IGV angle. After IGV angle was changed from 4 deg to 3 deg, NGP can reach 100% at T5 only 1180 F. The problem is solved.
Moral of the story =
the truth is out there.
never believe anything untill you reconfirm it.
Startup
Selamat datang di webnya insinyur agak-agak tuli.
Terima kasih banyak Anda telah meluangkan waktu untuk berkunjung.
Rotating Engineer adalah titel profesi seorang insinyur teknik mesin dengan spesialisasi keahlian di bidang mesin-mesin berputar, misalnya turbin gas, kompresor sentrifugal, pompa sentrifugal, screw compressor, reciprocating engine, dan fin fan cooler. Seorang Rotating Engineer bertanggung jawab untuk membuat agar mesin-mesin itu dapat beroperasi dengan baik dan benar.
Blog ini berisi hal-hal yang berkaitan dengan profesi seorang Rotating Engineer. Isinya diambil dari pengalaman sehari-hari, berbagai sumber referensi, dan opini pribadi saya. Topik-topiknya dapat dilihat dengan meng-klik nama bulan yang ada di kotak "ARTIKEL" di sebelah kiri.
Diharapkan dari blog ini pembaca dapat mengambil manfaat yang sebanyak-banyaknya. Pertanyaan, diskusi, dan saran sangat saya harapkan. Bisa kontak ke saya di: rotatingengineer@gmail.com.
DISCLAIMER
Saya tidak bertanggung jawab atas segala akibat yang terjadi karena blog ini. Blog ini hanya berisi opini dan pengalaman pribadi saya saja.
Sekali lagi: terima kasih banyak.
wasalam
Terima kasih banyak Anda telah meluangkan waktu untuk berkunjung.
Rotating Engineer adalah titel profesi seorang insinyur teknik mesin dengan spesialisasi keahlian di bidang mesin-mesin berputar, misalnya turbin gas, kompresor sentrifugal, pompa sentrifugal, screw compressor, reciprocating engine, dan fin fan cooler. Seorang Rotating Engineer bertanggung jawab untuk membuat agar mesin-mesin itu dapat beroperasi dengan baik dan benar.
Blog ini berisi hal-hal yang berkaitan dengan profesi seorang Rotating Engineer. Isinya diambil dari pengalaman sehari-hari, berbagai sumber referensi, dan opini pribadi saya. Topik-topiknya dapat dilihat dengan meng-klik nama bulan yang ada di kotak "ARTIKEL" di sebelah kiri.
Diharapkan dari blog ini pembaca dapat mengambil manfaat yang sebanyak-banyaknya. Pertanyaan, diskusi, dan saran sangat saya harapkan. Bisa kontak ke saya di: rotatingengineer@gmail.com.
DISCLAIMER
Saya tidak bertanggung jawab atas segala akibat yang terjadi karena blog ini. Blog ini hanya berisi opini dan pengalaman pribadi saya saja.
Sekali lagi: terima kasih banyak.
wasalam
Tampilkan postingan dengan label turbine. Tampilkan semua postingan
Tampilkan postingan dengan label turbine. Tampilkan semua postingan
Sabtu, 28 Juni 2008
Jumat, 07 Maret 2008
Bagaimana Cara Menghitung Power Output Gas Turbin di Lapangan?
Yg sering pake ngeliat kurva performance. Lebih enak euy..
Kalau pake ngitung ribet.
1. Bisa pake hitung dari torque meter (T):
POWER = 2 X pi x N x T
2. ngitung termodinamika. Utk open cycle:
Work aktual kompresor = entalpi spesifik di titik keluar kompresor – entalpi spesifik di inlet kompresor
Work aktual turbin = [1+(laju aliran massa fuel/laju aliran massa udara)] x (entalpi spesifik sebelum masuk turbin – entalpi spesifik setelah keluar turbin)
Kerja net shaft turbin = work aktual turbin – work aktual kompressor
Power output = laju aliran massa aktual x kerja net turbin shaft
Ente tinggal mengkonversi data-data PCD, Tinlet compressor, T emp PCD, TRIT, Texhast, inlet air pressure, fuel flow, fuel heating value, S.G fuel, ambient temperature ke entalpi dan mass flowrate.
Cuma kalo mau ngukur-ngukur harus ada limit max fluktuasi datanya (lihat PTC-10)
3. derating dari data nameplate.
Power available at site = ISO rated HP x altitude correction factor x inlet loss correction factor x exhaust loss correction factor x ambient temperature correction factor
4. Hitung mundur dari power yg di drive, misalnya pompa, kW yg dibangkitkan, gas yang dikompres, dll. Cuma musti hati-hati dalam menentukan efisiensi gearbox, kopling, isentropic efisiensi, efisiensi pompa, efisiensi alternator, ataupun efisiensi pentransmisian daya lainnya.
trims.
Kalau pake ngitung ribet.
1. Bisa pake hitung dari torque meter (T):
POWER = 2 X pi x N x T
2. ngitung termodinamika. Utk open cycle:
Work aktual kompresor = entalpi spesifik di titik keluar kompresor – entalpi spesifik di inlet kompresor
Work aktual turbin = [1+(laju aliran massa fuel/laju aliran massa udara)] x (entalpi spesifik sebelum masuk turbin – entalpi spesifik setelah keluar turbin)
Kerja net shaft turbin = work aktual turbin – work aktual kompressor
Power output = laju aliran massa aktual x kerja net turbin shaft
Ente tinggal mengkonversi data-data PCD, Tinlet compressor, T emp PCD, TRIT, Texhast, inlet air pressure, fuel flow, fuel heating value, S.G fuel, ambient temperature ke entalpi dan mass flowrate.
Cuma kalo mau ngukur-ngukur harus ada limit max fluktuasi datanya (lihat PTC-10)
3. derating dari data nameplate.
Power available at site = ISO rated HP x altitude correction factor x inlet loss correction factor x exhaust loss correction factor x ambient temperature correction factor
4. Hitung mundur dari power yg di drive, misalnya pompa, kW yg dibangkitkan, gas yang dikompres, dll. Cuma musti hati-hati dalam menentukan efisiensi gearbox, kopling, isentropic efisiensi, efisiensi pompa, efisiensi alternator, ataupun efisiensi pentransmisian daya lainnya.
trims.
Labels:
efficiency,
enthalpy,
gas,
horsepower,
isentropic,
output,
power,
PTC10,
PUMP,
shaft,
turbine
Jumat, 11 Januari 2008
Pencucian Turbin Gas

Pencucian turbin gas atau biasa disebut dengan istilah crankwash, cranksoak wash, atau fire wash. Pada cranksoak wash dan crankwash digunakan detergen sedangkan fire wash hanya menggunakan air distillate (air suling). Untuk tiap manufacturer turbin gas merekomendasikan penggunanaa distillate water dengan syarat tertentu (misalnya kadar maksimum senyawa dalam distillate water yang diizinkan: chlorides, total dissolved salt, sulphates, acidity, silica, specific conductance), detergen apa saja yang diperbolehkan, konsentrasi pencampuran antara deterjen dengan water, samapai seberapa bersih pencucian dilakukan, serta frekwensi pencucian.
Tujuan pencucian turbin ini adalah untuk mempertahankan performa engine dengan cara meredam tingkat pertambahan fouling pada sudu-sudu compressor gas turbine. Adanya fouling ini menyebabkan efisiensi aerodinamis sudu-sudu berkurang yang ditandai dengan berkurangnya pressure kompresi dari final stage compressor (discharge compressor pressure). Jadi untuk mengkompensasikan kekurangan pressure ini, untuk mendapatkan gas turbine power output yang sama, maka konsumsi fuel akan meningkat. Sehingga indikasi yang dapat dipakai untuk menentukan kapan saat yang tepat untuk melakukan crankwash atau fie wash adalah: compressor discharge pressure, bellmouth static pressure, dan/atau combustor exhaust temperature.
Contohnya: Rolls Royce Avon 1535-G121 disarankan untuk dilakukan fire wash jika terjadi penurunan 3% bellmouth static pressure.
trims.
Tujuan pencucian turbin ini adalah untuk mempertahankan performa engine dengan cara meredam tingkat pertambahan fouling pada sudu-sudu compressor gas turbine. Adanya fouling ini menyebabkan efisiensi aerodinamis sudu-sudu berkurang yang ditandai dengan berkurangnya pressure kompresi dari final stage compressor (discharge compressor pressure). Jadi untuk mengkompensasikan kekurangan pressure ini, untuk mendapatkan gas turbine power output yang sama, maka konsumsi fuel akan meningkat. Sehingga indikasi yang dapat dipakai untuk menentukan kapan saat yang tepat untuk melakukan crankwash atau fie wash adalah: compressor discharge pressure, bellmouth static pressure, dan/atau combustor exhaust temperature.
Contohnya: Rolls Royce Avon 1535-G121 disarankan untuk dilakukan fire wash jika terjadi penurunan 3% bellmouth static pressure.
trims.
Labels:
aeroderivative,
avon,
cranksoakwash,
crankwash,
firewash,
gas,
industrial,
offshore,
onshore,
turbine